I did an initial post on the topic of latency back in June [link], shown below is a more complete list of latency measurements for various Digital View LCD controllers. For many applications the latency caused by buffering and image processing in the controller is not an issue, however with the increase in interactive display systems in digital signage and corporate AV it is getting more attention. We recently ran tests using a third party input signal to image latency tester designed to provide a consistent methodology and basis for comparison.
LCD Controller model | Latency (ms) |
Date Added |
SVX-4096 (60Hz LCD panel) | 15ms | 16 Oct 2016 |
SVX-4096 (120Hz LCD panel) | 23ms | 16 Oct 2016 |
SVX-2560 | 35ms | 16 Oct 2016 |
SVX-1920v3 | 44ms | 16 Oct 2016 |
ALR-1920 / DD-1920 | 11ms | 16 Oct 2016 |
ALT-1920 | 13ms | 12 Apr 2019 |
ALR-1400 / HE-1400 | 13ms | 16 Oct 2016 |
The timing is measured on a consistent basis using an input signal timed to the middle rows of the display.
For more information contact us here…
Leave a Reply